Medical policy: Positron Emission Mammography

Policy number: MP 5.008

Clinical benefit

  • Minimize safety risk or concern.
  • Minimize harmful or ineffective interventions.
  • Assure appropriate level of care.
  • Assure appropriate duration of service for interventions.
  • Assure that recommended medical prerequisites have been met.
  • Assure appropriate site of treatment or service.

Effective date: 11/1/2026

Policy

Positron emission mammography (PEM)

The use of positron emission mammography (PEM) is considered investigational. There is insufficient evidence to support a general conclusion concerning the health outcomes or benefits associated with this procedure.

Note: For the use of mammography for preventive screening for adult Members covered under commercial products, refer to the Schedule of Preventive Care Services.

Cross-reference

  • MP 5.021 Scintimammography and Gamma Imaging of the Breast and Axilla

Product variations

This policy is only applicable to certain programs and products administered by Capital Blue Cross and subject to benefit variations. Please see additional information below.

FEP PPO - Refer to Section VI of the FEP Medical Policy Manual. The FEP Medical Policy Manual can be found at: FEP Medical Policy Manual.

Note: On October 5, 2015, the Pennsylvania Insurance Department provided guidance to health Insurers regarding coverage of 3D Mammography (Digital Breast Tomosynthesis) Under this state law, 3D mammograms, also known as digital breast tomosynthesis, must be covered at no cost in the same manner as traditional two-dimensional mammograms.

Description/Background

Positron emission mammography (PEM)

Positron emission mammography (PEM) is a form of positron emission tomography (PET) that uses a high-resolution, mini-camera detection technology for imaging the breast. As with PET, a radiotracer (usually fluorine 18 fluorodeoxyglucose) is administered, and the camera is used to provide a higher resolution image of a limited section of the body than would be achievable with fluorine 18 fluorodeoxyglucose PET. Gentle compression is used, and the detector(s) are mounted directly on the compression paddle(s).

PEM was developed to overcome the limitations of PET for detecting breast cancer tumors. Patients are usually supine for PET procedures; further, breast tissue may spread over the chest wall, making it potentially difficult to differentiate breast lesions from other organs that take up the radiotracer. PET’s resolution is generally limited to approximately 5 mm, which may not detect early breast cancer tumors. PEM allows for the detection of lesions as small as 2 to 3 mm and creates images that are more easily compared with mammography because they are acquired in the same position. Three-dimensional reconstruction of PEM images also is possible. As with PET, PEM provides functional rather than anatomic information about the breast. In PEM studies, exclusion criteria have included some patients with diabetes (e.g., Berg et al [2011, 2012]).

Radiation dose associated with PEM

The label-recommended dose of FDG for PEM is 370 MBq (10 mCi). Hendrick (2010) calculated mean glandular doses, and from the doses was able to determine lifetime attributable risk (LAR) of cancer for film mammography, digital mammography, breast-specific gamma imaging (BSGI), and PEM.8 The author used BEIR VII Group risk estimates to gauge the risks of radiation-induced cancer incidence and mortality from breast imaging studies. Estimated LAR of cancer for a patient with average-sized compressed breast during mammography of 5.3 cm (risks would be higher for larger breasts) for a single breast procedure at age 40 years is:

  • 5 per 100,000 for digital mammography (breast cancer only);
  • 7 per 100,000 for screen film mammography (breast cancer only);
  • 55 to 82 per 100,000 for BSGI (depending on the dose of technetium 99m sestamibi); and
  • 75 per 100,000 for PEM.

The corresponding LAR of cancer mortality at age 40 years is:

  • 1.3 per 100,000 for digital mammography (breast cancer only);
  • 7 per 100,000 for screen film mammography (breast cancer only);
  • 26 to 39 per 100,000 for BSGI; and
  • 31 per 100,000 for PEM.

A major difference in the impact of radiation between mammography and BSGI or PEM is that in mammography radiation dose is limited to the breast; whereas with BSGI and PEM, all organs are irradiated. Furthermore, as one ages, the risk of cancer induction from radiation exposure decreases more rapidly for the breast than for other radiosensitive organs. Organs at highest risk for cancer are the bladder with PEM and the colon with BSGI; these cancers, along with lung cancer, are also less curable than breast cancer. Thus, the distribution of radiation throughout the body adds to the risks associated with BSGI and PEM. Hendrick concluded that:

“… BSGI and PEM are not good candidate procedures for breast cancer screening because of the associated higher risks for cancer induction per study compared with the risks associated with existing modalities such as mammography, breast US [ultrasound], and breast MR [magnetic resonance] imaging. The benefit-to-risk ratio for BSGI and PEM may be different in women known to have breast cancer, in whom additional information about the extent of disease may better guide treatment.”

O’Connor et al (2010) estimated the LAR of cancer and cancer mortality from the use of digital mammography, screen-film mammography, PEM, and molecular breast imaging. Only results for digital mammography and PEM are reported here. The authors concluded that, in a group of 100,000 women at age 80 years, a single digital mammogram at age 40 years would induce 4.7 cancers with 1.0 cancer deaths; 2.2 cancers with 0.5 cancer deaths for a mammogram at age 50; 0.9 cancers with 0.2 cancer deaths for a mammogram at age 60; and 0.2 cancers with 0.0 cancer deaths for a mammogram at age 70. Comparable numbers for PEM would be 36 cancers and 17 cancer deaths for PEM at age 40; 30 cancers and 15 cancer deaths for PEM at age 50; 22 cancers and 12 cancer deaths for PEM at age 60; and 9.5 cancers and 5.2 cancer deaths for PEM at age 70. The authors also analyzed the cumulative effect of annual screening between the ages of 40 and 80, as well as between the ages of 50 and 80. For women at age 80 who were screened annually from the ages of 40 to 80, digital mammography would induce 56 cancers with 15 cancer deaths; for PEM, the analogous numbers were 800 cancers and 408 cancer deaths. For women at age 80 who were screened annually from the ages of 50 to 80, digital mammography would induce 21 cancers with 6 cancer deaths; for PEM, the analogous numbers were 442 cancers and 248 cancer deaths. However, background radiation from age 0 to 80 is estimated to induce 2174 cancers and 1011 cancer deaths.

These calculations, like all estimated health effects of radiation exposure, are based on several assumptions. When comparing digital mammography with PEM, 2 conclusions become clear: Many more cancers are induced by PEM than by digital mammography; and for both modalities, adding annual screening from age 40 to 49 roughly doubles the number of induced cancers. In a benefit-risk calculation performed for digital mammography but not for PEM, O’Connor et al (2010) nevertheless reported that the benefit-risk ratio of annual screening is still approximately 3 to 1 for women in their 40s, although it is much higher for women age 50 and older. Like Hendrick, the authors concluded that “if molecular imaging techniques [including PEM] are to be of value in screening for breast cancer, then the administered doses need to be substantially reduced to better match the effective doses of mammography.”

The American College of Radiology has assigned a relative radiation level (effective dose) of 10 to 30 mSv to PEM. The College has also stated that, because of radiation dose, PEM and BSGI in their present form are not indicated for screening.

Because the use of BSGI and molecular breast imaging have been proposed for women at high risk of breast cancer, it should be noted there is controversy and speculation whether some women (e.g., those with BRCA variants) have heightened radiosensitivity. If women with BRCA variants are more radiosensitive than the general population, the previous estimates may underestimate the risks they face from breast imaging with ionizing radiation (i.e., mammography, BSGI, molecular breast imaging, PEM, single-photon emission computed tomography, breast-specific computed tomography, and tomosynthesis; ultrasound and magnetic resonance imaging do not use radiation). More research will be needed to resolve this issue. Also, risks associated with radiation exposure will be greater for women at high risk of breast cancer (regardless of whether they are more radiosensitive) because they start screening at a younger age when the risks associated with radiation exposure are increased.

Regulatory status

In 2003, the PEM 2400 PET Scanner (PEM Technologies) was cleared for marketing by the U.S. Food and Drug Administration (FDA) through the 510(k) process. FDA determined that this device was substantially equivalent to existing devices for “medical purposes to image and measure the distribution of injected positron emitting radiopharmaceuticals in human beings for the purpose of determining various metabolic and physiologic functions within the human body.”

In 2009, the Naviscan PEM Flex™ Solo II™ High Resolution PET Scanner (Naviscan) was cleared for marketing by FDA through the 510(k) process for the same indication. The PEM 2400 PET Scanner was the predicate device. The newer device has been described by the manufacturer as “a high spatial resolution, small field-of-view PET imaging system specifically developed for close-range, spot, ie, limited field, imaging.”

In 2013, Naviscan was acquired by Compañía Mexicana de Radiología SA, which currently markets the Naviscan Solo II™ Breast PET Scanner in the United States (CMR Naviscan). FDA product code: KPS.

Rationale

Positron emission mammography

Summary of evidence

For individuals who are being screened for breast cancer the evidence includes a retrospective study. Relevant outcomes are overall survival, disease-specific survival, test accuracy and validity, and resource utilization. It has not been demonstrated that PEM provides better diagnostic accuracy than the relevant comparators nor has PEM been shown to provide clinical utility. In addition, without demonstrated advantages in clinical utility, the relatively high radiation dosage associated with PEM does not favor its use given that alternative tests deliver lower doses. The evidence is insufficient to determine the effects of the technology on health outcomes.

For individuals with clinically localized breast cancer undergoing presurgical evaluation, the evidence includes prospective studies. Relevant outcomes are overall survival, disease-specific survival, test accuracy and validity, and resource utilization. It has not been demonstrated that PEM provides better diagnostic accuracy than the relevant comparators nor has PEM been shown to provide clinical utility. In addition, without demonstrated advantages in clinical utility, the relatively high radiation dosage associated with PEM does not favor its use given that alternative tests deliver lower doses. The evidence is insufficient to determine the effects of the technology on health outcomes.

For individuals with a suspicious breast lesion on conventional breast cancer evaluation, the evidence includes prospective studies as well as a meta-analysis. Relevant outcomes are overall survival, disease-specific survival, test accuracy and validity, and resource utilization. It has not been demonstrated that PEM provides better diagnostic accuracy than the relevant comparators nor has PEM been shown to provide clinical utility. In addition, without demonstrated advantages in clinical utility, the relatively high radiation dosage associated with PEM does not favor its use given that alternative tests deliver lower doses. The evidence is insufficient to determine the effects of the technology on health outcomes.

Practice guidelines and position statements

National Comprehensive Cancer Network

The 2026 NCCN Clinical Practice Guideline for Breast Cancer Screening and Diagnosis states: “Limited data exist regarding the use of MBI for breast cancer screening; however, screening MBI has similar sensitivity but improved specificity compared to ultrasounds in studies with individuals with dense breasts. Additionally, MBI has a whole-body effective radiation dose higher than of mammography”

American College of Radiology

The ACR appropriateness criteria palpable breast masses mentions “there is little role for advanced technologies such as MRI, positron emission mammography or molecular breast imaging in the evaluation of a palpable mass.”

In 2017, the American College of Radiology has included positron emission mammography (PEM) in its criteria on breast screening. PEM was rated as “usually not appropriate” for screening women at average- or high-risk for breast cancer. The College has also assigned a relative radiation level (effective dose) of 10 to 30 mSv to PEM and stated that PEM is limited “by radiation dose and lack of evidence in large screening population.”

Definitions

N/A

Disclaimer

Capital Blue Cross’ medical policies are used to determine coverage for specific medical technologies, procedures, equipment, and services. These medical policies do not constitute medical advice and are subject to change as permitted by law or applicable clinical evidence from independent treatment guidelines. Treating providers are solely responsible for medical advice and treatment of members. These polices are not a guarantee of coverage or payment. Payment of claims is subject to a determination regarding the member’s benefit program and eligibility on the date of service, and a determination that the services are medically necessary and appropriate. Final processing of a claim is based upon the terms of contract that applies to the members’ benefit program, including benefit limitations and exclusions. If a provider or a member has a question concerning this medical policy, please contact Capital Blue Cross’ Provider Services or Member Services.

Coding information

Note: This list of codes may not be all-inclusive, and codes are subject to change at any time. The identification of a code in this section does not denote coverage as coverage is determined by the terms of member benefit information. In addition, not all covered services are eligible for separate reimbursement.

Investigational when used to report positron emission mammography (PEM); therefore, not covered

Procedure codes

78999

 

 

 

 

References

  1. Birdwell RL, Mountford CE, Iglehart JD. Molecular imaging of the breast. AJR Am J Roentgenol. Aug 2009;193(2):367-376. PMID 19620433
  2. Eo JS, Chun IK, Paeng JC, et al. Imaging sensitivity of dedicated positron emission mammography in relation to tumor size. Breast. Feb 2012;21(1):66-71. PMID 21871801
  3. Tafreshi NK, Kumar V, Morse DL, et al. Molecular and functional imaging of breast cancer. Cancer Control. Jul 2010;17(3):143-155. PMID 20664511
  4. Prekeges J. Breast imaging devices for nuclear medicine. J Nucl Med Technol. Jun 2012;40(2):71-78. PMID 22562462
  5. Shkumat NA, Springer A, Walker CM, et al. Investigating the limit of detectability of a positron emission mammography device: a phantom study. Med Phys. Sep 2011;38(9):5176-5185. PMID 21978062
  6. Berg WA, Madsen KS, Schilling K, et al. Breast cancer: comparative effectiveness of positron emission mammography and MR imaging in presurgical planning for the ipsilateral breast. Radiology. Jan 2011;258(1):59-72. PMID 21076089
  7. Berg WA, Madsen KS, Schilling K, et al. Comparative effectiveness of positron emission mammography and MRI in the contralateral breast of women with newly diagnosed breast cancer. AJR Am J Roentgenol. Jan 2012;198(1):219-232. PMID 22194501
  8. Hendrick RE. Radiation doses and cancer risks from breast imaging studies. Radiology. Oct 2010;257(1):246-253. PMID 20736332
  9. Research Council of the National Academies. Health risks from exposure to low levels of ionizing radiation: BEIR VII, Phase 2--Committee to Assess Health Risks for Exposure to Low Levels of Ionizing Radiation. Washington, DC: National Academies Press; 2006.
  10. O'Connor MK, Li H, Rhodes DJ, et al. Comparison of radiation exposure and associated radiation-induced cancer risks from mammography and molecular imaging of the breast. Med Phys. Dec 2010;37(12):6187-6198. PMID 21302775
  11. American College of Radiology (ACR). ACR Appropriateness Criteria® breast cancer screening. 2017.
  12. Berrington de Gonzalez A, Berg CD, Visvanathan K, et al. Estimated risk of radiation-induced breast cancer from mammographic screening for young BRCA mutation carriers. J Natl Cancer Inst. Feb 4 2009;101(3):205-209. PMID 19176458
  13. Ernestos B, Nikolaos P, Koulis G, et al. Increased chromosomal radiosensitivity in women carrying BRCA1/BRCA2 mutations assessed with the G2 assay. Int J Radiat Oncol Biol Phys. Mar 15 2010;76(4):1199-1205. PMID 20206018
  14. Food and Drug Administration (FDA). 510(k) Summary: PEM 2400 PET Scanner. 2003.
  15. Fikes BJ. Naviscan's assets sold to Mexican company San Diego Union-Tribune. Dec 11, 2013
  16. Yamamoto Y, Tasaki Y, Kuwada Y, et al. A preliminary report of breast cancer screening by positron emission mammography. Ann Nucl Med. Feb 2016;30(2):130-137. PMID 26586370
  17. Schilling K, Narayanan D, Kalinyak JE, et al. Positron emission mammography in breast cancer presurgical planning: comparisons with magnetic resonance imaging. Eur J Nucl Med Mol Imaging. Jan 2011;38(1):23-36. PMID 20871992
  18. Narayanan D, Madsen KS, Kalinyak JE, et al. Interpretation of positron emission mammography and MRI by experienced breast imaging radiologists: performance and observer reproducibility. AJR Am J Roentgenol. Apr 2011;196(4):971-981. PMID 21427351
  19. Narayanan D, Madsen KS, Kalinyak JE, et al. Interpretation of positron emission mammography: feature analysis and rates of malignancy. AJR Am J Roentgenol. Apr 2011;196(4):956-970. PMID 21427350
  20. Tafra L, Cheng Z, Uddo J, et al. Pilot clinical trial of 18F-fluorodeoxyglucose positron-emission mammography in the surgical management of breast cancer. Am J Surg. Oct 2005;190(4):628-632. PMID 16164937
  21. Caldarella C, Treglia G, Giordano A. Diagnostic performance of dedicated positron emission mammography using fluorine-18-fluorodeoxyglucose in women with suspicious breast lesions: a meta-analysis. Clin Breast Cancer. Aug 2014;14(4):241-248. PMID 24472718
  22. Berg WA, Weinberg IN, Narayanan D, et al. High-resolution fluorodeoxyglucose positron emission tomography with compression ("positron emission mammography") is highly accurate in depicting primary breast cancer. Breast J. Jul-Aug 2006;12(4):309-323. PMID 16848840
  23. Muller FH, Farahati J, Muller AG, et al. Positron emission mammography in the diagnosis of breast cancer. Is maximum PEM uptake value a valuable threshold for malignant breast cancer detection? Nuklearmedizin. Dec 2016;55(1):15-20. PMID 26627876
  24. National Comprehensive Cancer Network (NCCN). NCCN Clinical Practice Guidelines in Oncology: Breast Cancer Screening and Diagnosis. Version 1.2026
  25. American College of Radiology (ACR). ACR Appropriateness Criteria® Palpable Breast Masses. 2017.
  26. Slanetz P. Screening for breast cancer: MRI of the breast and emerging technologies. In: UpToDate Online Journal [serial online]. Waltham, MA: UpToDate; updated February 14, 2023.
  27. U.S. Preventive Services Task Force. Screening for Breast Cancer. Updated September 3, 2019.
  28. Venkataraman S. Breast Imaging for Cancer Screening: Mammography and Ultrasonography. In: UpToDate Online Journal [serial online]. Waltham, MA: UpToDate; updated September 21, 2021
  29. The American Society of Breast Surgeons. Consensus Guidelines on Diagnostic and Screening Magnetic Resonance Imaging of the Breast. June 22, 2017
  30. Keshavarz K, Jafari M et al. Positron Emission Mammography (PEM) in the Diagnosis of Breast Cancer: A Systematic Review and Economic Evaluation. Medical Journal of the Islamic Republic of Iran. August 18, 2020. PMID: 33315994
  31. Patel MM, Adrada BE, Fowler AM, Rauch GM. Molecular Breast Imaging and Positron Emission Mammography. PET Clin. 2023;18(4):487-501. PMID 37258343
  32. Freitas V, Li X, Scaranelo AM, et al. Breast cancer detection using a Low-Dose Positron emission digital mammography system. Radiology Imaging Cancer. 2024;6(2). doi:10.1148/rycan.230020
  33. Slanetz P. MRI of the breast and emerging technologies. In: UpToDate Online Journal [serial online]. Waltham, MA: UpToDate; updated January 2024. Literature review current through March 2024.

Policy history

MP 5.008

09/16/2020 Consensus review. No change to policy Statement. Coding reviewed, no changes; Product Variation Statement updated; References reviewed, updated.

01/15/2021 Administrative update. Note on preventive mammography updated to reflect the appropriate document.

12/02/2021 Major review. Removed criteria for mammogram, continues to be covered service. Update to background, rationale, coding, and references to reflect this change.

10/20/2022 Consensus review. Policy statement unchanged. References updated.

04/07/2023 Consensus review. Policy statement unchanged. References updated.

04/10/2024 Consensus review. No change to policy statement. References updated. Coding reviewed with no coding changes.

06/16/2025 Consensus review. No changes to policy statement. Coding reviewed and no changes.

09/04/2025 Administrative update. Removed NCCN Statement, Benefit Variations Section and updated Disclaimer.

07/09/2026 Consensus review. No change to policy statement. Supporting paragraphs moved for clarity. References and Background reviewed and updated. Intent unchanged.